CPM 8000 

Fabricante : Carewell 

   

CPM-8000 Multi-parameter Patient Monitor

Features

  • Application of embedded system and high integrated, intelligent   Modular   technology
  • Suitable for adults, pediatrics, or neonates
  • 8.4″ high resolution TFT display with 7 waveforms
  • 72 hours' trend recall
  • ST segment, auto detection of lead-off
  • Function of Oxy-CRG analysis
  • Protection against electro-tome, defibrillator or pace-maker interference
  • Net work function

Standard parameters: 

  • ECG, NIBP, SPO2, RESP, TEMP, PR

Optional: 

  • Built-in thermal recorder
  • Dual-IBP
  • EtCo2

Specification

Environment
Operating: Temperature 5~40℃ Humidity = 80%
Storage: Temperature -20~55℃ Humidity = 93%

Power
DC: Built-in rechargeable battery, 2 hours working time
AC : 85-260V 50/60Hz ±0%


Display
8.4″ TFT, 800*600
Maximum 7 waveforms in full screen
Power/standby indicator and battery indicator


Battery
Rechargeable 12V Acid battery
Regular working time above 2 hours
Lasting 5 minutes after first alarm of low battery


Recorder
Built-in, thermal array
Recording mode: manual, alarm and timing
Parameter alarm recording
Waveform freeze recording
Trend list/graph recording
Alarm event review recording
NIBP review recording
Monitor information recording


Recall
Trend recall: 72hours, I-minute resolution
Alarm event recall: all parameters
NIBP measurement recall: .1400 NIBP measurement data


EGC
Displaying graphics of 7 leads on the same screen
Overload protection: Defibrillation.
Anti the interference of high-frequency electrotome
Lead: 5 leads (RA, LA, V, RL, LL)
Lead Selection: I; II; III; avR; avL; avF; V;
Waveform: 7 channels
Gain Selection: ×0. 5; ×1; ×2; ×4
Electrical Leakage : < 30uA
Baseline Recovery Time: <3 sec following defibrillation
Protection: separates and withstands, 4000V AC/50Hz
defibrillation,resistent to interference of
electrotonus and myoelectricity
Scan Speed: 12.5mm/25mm/50mm/sec
Lead Drop: auto detection
Modes: DIA: 0.05~100Hz
MON: 0.5~35Hz
OPE: 1~25Hz

RESP
Model: RA-LL impedance
Measurement /alarm range:199 rpm
Resolution: 1rpm.
Accuracy: ±2rpm.

NIBP
Unique Direct, Reverse and Quick modes
Method: automatic oscillometric
Working Mode: Auto/Manual
Interval of Auto Mode: 1-60 min
PR Range: 0-300 bpm
Measurement Unit: mmHg/Kpa Selectable
Measurement Ranges: Systolic BP,
Diastolic BP and Mean BP
Applicability: Adult/Pediatric/Neonatal
Overload protection: Dual security protection

SpO
SpOprobe of high intensity and durability 2
Excellent measurement of low perfusion.
Anti interference of movement
Measurement Range: 0-100%
Alarm range: 0-100%
Resolution: ±1%
Accuracy: ±2% (80-100%)
±3% (60-79%)
PR range: 0~300bpm

HR
A. Measurement Range: 0-300bpm
B. Accuracy: ±1bpm or ±2%
C. Resolution: 1bpm
D. ECG Calibration: 1mV (Peak Value)
ST Segment offset (Diagnose Mode)
A. Measurement Range: -0.8mV~2.0mV
B. Accuracy: ±0.02mV or ±5%

TEMP
Resolution: 0.1 degrees Celsius
Accuracy: ±0.2 degrees Celsius
Channel: 1 channel
Average measurement Time: < 10sec
Alarm: Sound, light
Standard Configuration: ECG + RESP + NIBP + SpO 2
+ HR(PR) +TEMP
+ Built-in Battery
Optional Equipment: EtCo2, Single/Dual IBP, Builtin thermal recorder

 
  